CWC710000 series temperature sensor
2022年4月6日
CYBK0300 Series Explosion Proof Electronic Pressure Switch
2022年4月8日

CYBK0100 Series Electronic Pressure Switch


  1. Brief Introduction

CYBK series pressure switch is a measurement and control component integrating pressure measurement and control. This series of products mainly use silicon piezoresistive pressure sensor as the pressure sensitive core, and can also be equipped with ceramic capacitor, sapphire, sputtered film and other pressure sensors. After programmable digital circuit correction and signal conditioning, the standard industrial application signal and switching value signal are output. According to different use modes, the product can output 1 to 4 groups of switching signals, which can realize the control of up to 4 pressure points. The customer can set the switching point freely according to the use needs.

According to its own characteristics, CYBK series products can be divided into external modulation type, explosion-proof type, digital display type and other models to meet different application needs of users.

CYBK series pressure switches faithfully serve various fluid measurement industries with their excellent performance. Especially in water treatment, power, medicine, and other industries, it has good adaptability and application advantages.

CYBK0100   png.png

 

  1. Characteristics and Application

◆ external adjustable structure, easy to set

◆ there is no dead zone in the adjustment, and the     zero point to full scale can be adjusted arbitrarily

◆ full range coverage

◆ high stability and reliability

 

  1. Performance Index

    Parameter

    Parameter or Indicator

    Range

    -0.1MPa…0kPa~10kPa…100MPa

    Overload pressure

    Below 10MPa ≤ 2 times full scale

    10MPa and above ≤1.5 times full range

    Pressure type

    G(Gauge)、A(Absolute)、S(Seal gauge)

    Accuracy

    0.1(customized)

    0.25(Typical)

    0.5(Maximum)

    Long-term stability

    ±0.1%FS/年(Typical)

    ±0.2%FS/年(Maximum)

    Zero temperature drift

    ±0.03%FS/℃(≤100kPa)

    ±0.02%FS/℃(>100kPa)

    Sensitivity temperature drift

    ±0.03%FS/℃(≤100kPa)

    ±0.02%FS/℃(>100kPa)

    Compensation temperature

    0℃~50℃(≤100kPa)

    -10℃~70℃(>100kPa)

     Medium temperature

    -40℃~80℃

    Power supply

    12VDC~30VDC

    Output signal

    Relay contact

    Predetermined area

    Lower limit: 0 ~ upper limit and lowest value;

     Upper limit: lower limit maximum value ~ upper limit maximum value

    Protective level

    IP66

 

  1. Structural dimension drawing

CYBK0100   1.png

  1. Wiring

接线图.png

 

  1. Precautions

    6.1 Sealing measures shall be taken at the connection of pressure interface to prevent the leakage of pressurized liquid from causing pollution or accident.

    6.2 Filter and buffer measures shall be taken at the pressure interface end to prevent sensor damage caused by particles or impact.

    6.3 The temperature and humidity of the working environment shall meet the requirements of the product manual. If the environmental conditions are harsh, it must be explained when ordering.

    6.4 The sensing diaphragm of the pure flat film sensor is exposed. It is strictly prohibited to touch it in any form, otherwise it may cause irreversible damage to the transmitter.